---
title: Garmo-SerDes-28G | Garmo Labs
url: https://garmolabs.com/ip/garmo-serdes-28g
description: Adaptive serializer/deserializer control architecture; electrical rate and signal-integrity qualification are separate.
---

[Ip](https://garmolabs.com/marketplace) › IP-2093

Interfaces & mixed-signal

# Garmo-SerDes-28G

Adaptive serializer/deserializer control architecture; electrical rate and signal-integrity qualification are separate.

Evaluation package

[Request evaluation](https://garmolabs.com/contact?products=ip-ip-2093)

Gar Interfaces & mixed-signal

THE TECHNICAL ROLE

## A clear integration boundary.

Garmo-SerDes-28G integration role: High-Speed I/O — 224 Gb/s-class adaptive SerDes. Documented composition: TX FFE, RX CTLE/FFE/DFE with adaptive DSP and continuous calibration; ADC-based PAM4 receiver with programmable equalizer tap budget; Digital CDR, baud-rate adaptation and multi-protocol gearbox.

01

TX FFE, RX CTLE/FFE/DFE with adaptive DSP and continuous calibration

02

ADC-based PAM4 receiver with programmable equalizer tap budget

03

Digital CDR, baud-rate adaptation and multi-protocol gearbox

TECHNICAL OVERVIEW

## The details matter.

[Download the product brief](https://garmolabs.com/static/briefs/ip-ip-2093.pdf)

Canonical identity

IP-2093

Responsibility

High-Speed I/O — 224 Gb/s-class adaptive SerDes

Documented interface architecture

ADC/AFE/DAC hard-macro boundaries, PCS gearbox, FEC metrics, CSR, test pattern

Documented building blocks

TX FFE, RX CTLE/FFE/DFE with adaptive DSP and continuous calibration; ADC-based PAM4 receiver with programmable equalizer tap budget; Digital CDR, baud-rate adaptation and multi-protocol gearbox

Delivery boundary

Evaluation / IP scope

Evidence scope

Evaluation package

Architecture targets · not measurements

1–224 Gb/s/lane, NRZ/PAM4, 112 GBd PAM4; >50 dB channel-loss adaptation target; <4 pJ/bit PHY power target on leading node.

### Before integration.

Garmo-SerDes-28G integration role: High-Speed I/O — 224 Gb/s-class adaptive SerDes. Documented composition: TX FFE, RX CTLE/FFE/DFE with adaptive DSP and continuous calibration; ADC-based PAM4 receiver with programmable equalizer tap budget; Digital CDR, baud-rate adaptation and multi-protocol gearbox.

- Interface version and parameter set
- Clock/reset domains and integration constraints
- Companion memory, PHY and software requirements
- Verification collateral and acceptance criteria

The selected release must confirm:

- Node/library binding
- Clock/reset limits
- Physical and protocol dependencies
- Artifact hashes
- Acceptance criteria

Unpublished values are not inferred from family names or architecture targets.

[Discuss the integration](https://garmolabs.com/contact?products=ip-ip-2093)

Evaluation package

## Know the release.
Know what it establishes.

Canonical technology and its architecture/integration role are recorded. The offered delivery is confirmed against the exact release before licensing.

This is a controlled-portfolio summary, not a fresh execution of the chip qualification flow.

[Explore the evidence center](https://garmolabs.com/evidence) [Qualification record](https://garmolabs.com/qualification/ip-ip-2093)

### Release-specific qualification

Control/model IP does not establish analog PHY, electrical, RF or standards compliance. Qualified third-party or foundry collateral may be required.

Canonical record: P2 / REPRESENTATIVE ARCHITECTURE RTL — concrete integration specification and synthesizable RTL shell/representative datapath only; all frequency, throughput, power, area, jitter and standards-superiority figures remain architecture targets until the required evidence hierarchy closes. Electrical/PHY production claims require a characterized foundry/node hard-macro backend plus package/channel and compliance evidence.

A PATH THAT FITS THE PROJECT

## Build with Garmo-SerDes-28G.

Technical scope, rights, support and release configuration are agreed before delivery.

evaluation

### Evaluate an individual IP configuration

Inspect the named release and establish technical fit.

[Discuss this scope](https://garmolabs.com/contact?products=ip-ip-2093&scope=evaluation)

production

### Named-design production license

Agree deployment or design rights, deliverables and support.

[Discuss this scope](https://garmolabs.com/contact?products=ip-ip-2093&scope=production)

custom

### Node binding or derivative integration

Define the customer-specific work and acceptance criteria.

[Discuss this scope](https://garmolabs.com/contact?products=ip-ip-2093&scope=custom)

## Keep exploring.

Interfaces & mixed-signal

[## GSH-130A](https://garmolabs.com/ip/gsh-130a)

Analog socket contract; digital management; calibration firmware path; AMS smoke flow; PEX/LVS/ERC/PVT collateral.

Qualified release

IP-004 · Controlled physical release

Interfaces & mixed-signal

[## Garmo-CAN-FD-CTL](https://garmolabs.com/ip/garmo-can-fd-ctl)

Automotive CAN controller architecture for message processing, timing and host integration.

Evaluation package

IP-2086 · Source documented

Interfaces & mixed-signal

[## Garmo-LIN-CTL](https://garmolabs.com/ip/garmo-lin-ctl)

Automotive I/O — 8-channel autonomous LIN controller

Evaluation package

IP-2090 · Source documented

## Your next big idea.
Let’s build it together.

Start with a chip, a software release or a single IP block.

[Talk to Garmo](https://garmolabs.com/contact) [Start exploring](https://garmolabs.com/developers)

CANONICAL EVIDENCE RECORD · IP-2093

### Source documented

A concrete source or implementation record exists; the selected evidence does not establish complete qualification.

**Record integrity and qualification boundary**Retained exact-release source reference; no new table locator was inferred.

Evidence ranking for evaluation prioritization; not a probability or certification.

[How evidence priority is determined ](https://garmolabs.com/marketplace/evidence)
